DMU330-6000.3/4CK-M12 Part no.: 50136117
Ultrasonic distance sensors
หมวดหมู่ : Distance and Measuring sensors ,  Ultrasonic distance sensors , 
แบรนด์ : Leuze
Share
คุณสมบัติ
Basic data
Series 330
Contains 2x M30 mounting nut
Special version
Special version Multiplex operation
Synchronous operation
Optical data
Opening angle 9 °
Direction of beam Front
Measurement data
Measurement range 350 ... 6,000 mm
Resolution 6 mm
Accuracy 1 %
Reference value, accuracy End value
Repeatability 0.5 %
Reference value repeatability End value
Temperature drift 8 %
Electrical data
Protective circuit Inductive protection
Polarity reversal protection
Short circuit protected
Performance data
Supply voltage UB 12 ... 30 V, DC
Residual ripple 0 ... 5 %, From UB
Open-circuit current 0 ... 50 mA
Switching hysteresis 1 %
Outputs
Number of analog outputs 1 Piece(s)
Number of digital switching outputs 1 Piece(s)
Load resistance 0 ... 500 Ω
Characteristic curve Rising / falling
Analog outputs
Current 4 ... 20 mA
Analog output 1
Type Current
Switching outputs
Switching current, max. 100 mA
Switching output 1
Switching element Transistor, PNP
Switching principle NO (normally open)
Inputs/outputs selectable
Number of inputs/outputs selectable 1 Piece(s)
Input/output 1
Function Preventing mutual interference
Time behavior
Switching frequency 1 Hz
Ultrasonic frequency 75 kHz
Response time 500 ms
Connection
Connection 1
Type of connection Connector
Thread size M12
Material Plastic
No. of pins 5 -pin
Encoding A-coded
Mechanical data
Design Cylindrical
Thread size M30 x 1.5 mm
Dimension (Ø x L) 30 mm x 98.8 mm
Housing material Plastic
Plastic housing Polybutylene (PBT)
Sensing face material Plastic, Epoxy resin, glass fiber reinforced
Ultrasonic transducer material Piezoceramics (contains lead zirconium titanate (PZT))
Net weight 170 g
Operation and display
Type of display LED
Number of LEDs 3 Piece(s)
Operational controls Control buttons
Function of the operational control NC contact / NO contact changeover
Resetting to factory settings
Setting for the switching outputs/characteristic output curve
Environmental data
Ambient temperature, operation -20 ... 70 °C
Ambient temperature, storage -20 ... 70 °C
Certifications
Degree of protection IP 67
Protection class III
Certifications c UL US
Standards applied IEC 60947-5-2