Temperature transmitter Standard Class
Temperature
หมวดหมู่ : Process sensors ,  Temperature sensors , 
Share
คุณสมบัติ
General information
Range of application Liquid and gaseous media
Dew point resilience No
Pressure resistance 40 bar
Temperature measuring range min. -20 °C
Temperature measuring range max. 120 °C
Outputs / inputs
Analogue output 4 ... 20 mA
Comment on analogue output When used with an analog output use exclusively sensor cables without LED
IO-Link No
Electrical data
Operating voltage 12 ... 34 V DC
Voltage type Direct voltage (DC)
Electrical design PNP
Current consumption max. 20 mA
Protection class III
Short-circuit protection Yes
Overload-proof Yes
Reverse polarity protection Yes
Mechanical data
Materials in contact with the medium V2A (1.4305)
Copper
Probe diameter 6 mm
Material of housing V2A (1.4305)
PA
Electrical connection M12
2-pin
Process connection External thread
G 1/4
Installation length 50 mm
Accuracy
Response dynamics of T05 / T09 T05 = 6 s / T09 = 15 s
Comment *FS: Fullscale
Accuracy ± 0.2 K + max. 1.5 % FS*
Ambient conditions
Ambient temperature min. -30 °C
Ambient temperature max. 70 °C
Protection rating IP65