PBMH Series
Pressure sensors
หมวดหมู่ : Process sensors ,  Pressure sensors , 
แบรนด์ : Baumer
Share
Fully welded pressure transmitter for hygenic applications
Technical data
Performance characteristics
Measuring range -1 … 40 bar
Min. measuring span 0.1 bar
Max. measuring span 40 bar
Pressure type Absolute
Relative (gauged)
Standard error of measurement (BFSL) ± 0.04 % FSR
± 0.1 % FSR
Including non-linearity, hysteresis and non-repeatability according BFSL
For turndown, multiply this value by the applied turndown ratio
Max. measuring error ± 0.1 % FSR
± 0.25 % FSR
Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
For turndown, multiply this value by the applied turndown ratio
Temperature coefficient ≤ 0.03 % FSR/10 K , measuring span
≤ 0.03 % FSR/10 K , zero point
Compensated temperature range -40 … 85 °C
Long term stability ≤ 0.1 % FSR/a , measuring range > 1 bar
≤ 1 mbar , measuring range ≤ 1 bar
Max. turndown ratio 5 : 1
Rise time (10 ... 90 %) ≤ 5 ms
Compliance and approvals
Explosion protection ATEX II 1/2G Ex ia IIC T4/T6 Ga/Gb
ATEX II 1/2G Ex ia IIC T3/T4/T6 Ga/Gb
ATEX II 1D Ex ia IIIC T (200) 107 °C IP6X Da
ATEX II 1G Ex ia IIC T4/T6 Ga
ATEX II 1G Ex ia IIC T3/T4/T6 Ga
Data Sheet - PBMH Series Download