MC330-S1-C02M12-A Part no.: 63001107
Safety switches
หมวดหมู่ : Safety technology ,  Safety proximity sensors , 
Share
คุณสมบัติ
Basic data
Series MC330
Functions
Functions Integration in control circuits up to category4 in accordance with EN ISO 13849-1
Safety system in combination with an evaluation unit such as the MSI-MC310 safety relay or the MSI 400 safety controller.
Characteristic parameters
Mission time 20 years, EN ISO 13849-1
Category Up to 4, depending on evaluation, 1 sensor connected, EN ISO 13849-1
B10d 20,000,000 number of cycles
Electrical data
Protective circuit Current limitation
Short circuit protected,Via e.g. MSI-MC310, MSI 400
Contact allocation 1NC + 1NO
Contact type Reed contacts (magnetically sensitive)
Requirement on the voltage supply when used acc. to cULus (UL 508) Class 2 Circuits
Outputs
Max. switching voltage 27 V AC/DC
Switching current, max. 500 mA
Time behavior
Response time 3 ms
Connection
Number of connections 1 Piece(s)
Connection 1
Function Contact connection
Type of connection Cable with connector
Cable length 200 mm
Sheathing material PVC
Cable color Gray
Thread size M12
Material Metal
No. of pins 4 -pin
Mechanical data
Design Cylindrical
Thread size M30 x 3.5 mm
Dimension 36 mm
Housing material Plastic
Plastic housing Glass fiber reinforced (PPS), self-extinguishing
Net weight 122 g
Housing color Red
Type of fastening Mounting thread
Installation position Arbitrary, provided housing markings are aligned
Switch type Type 4 interlock device, contactless actuation, EN ISO 14119
Approach actuation directions 3-dimensional
Mechanical life time 10,000,000 actuation cycles
External actuator Magnetically coded
Cut-out point (OFF), min. 12 mm
Assured cut-out distance (Sar), min. 14 mm
Assured cut-in distance (Sao), max. 6 mm
Switching tolerance (without ferromagnetic materials in immediate vicinity) -1 ... 1 mm
Distance to other magnetic sensors, min. 50 mm
Approach speed, min. 0.05 m/s
Environmental data
Ambient temperature, operation -20 ... 70 °C
Degree of contamination 3, EN 60947-1
Certifications
Degree of protection IP 67
Certifications
TÜV Süd (with suitable safety relay) c UL US
Test procedure for EMC in accordance with standard EN 60947-5-3
EN 61000-6-2
EN 61000-6-3
Test procedure for oscillation in accordance with standard EN 60947-5-3
Test procedure for shock in accordance with standard EN 60947-5-3