Sensor for point level detection
Point level sensors
หมวดหมู่ : Process sensors ,  Level sensors , 
Share
คุณสมบัติ
General information
Range of application Water-based cooling lubricants, oils, water / media similar to water
Cannot be used for: See the operating instructions
Outputs / inputs
Switching output 2 x normally closed / normally open programmable
IO-Link Yes
Electrical data
Operating voltage 18 ... 30 V DC
Voltage type Direct voltage (DC)
Electrical design PNP
NPN*
*IO-Link parameterisation
Current carrying capacity max. 50 mA
Voltage drop max. 2.5 V
Current consumption max. 35 mA
Protection class III
Short-circuit protection Yes
Overload-proof Yes
Reverse polarity protection Yes
Mechanical data
Materials in contact with the medium V4A (1.4404)
FKM
PEEK
Material of housing PEI
V4A (1.4404)
FKM
PEEK
Electrical connection M12
4-pin
Contacts gold-plated
Process connection External thread
G 1/2
Probe length L9.6 mm Installation at rear
Ambient conditions
Ambient temperature min. -25 °C
Ambient temperature max. 85 °C
Maximum container pressure -1 ... 40 bar
Medium temperature -25 ... 100 °C °C
Protection rating IP68
IP69k