PLP70H
Point level sensors
หมวดหมู่ : Process sensors ,  Level sensors , 
แบรนด์ : Baumer
Share
Potentiometric level measurement
Technical data
Performance characteristics
Measuring principle Potentiometric level measurement
Media characteristics ≥ 5 µS/cm
Measuring range 200 … 3000 mm
Max. measuring error ± 1 % FSR ,for media conductivity ≥ 50 µS/cm
± 3 % FSR ,for media conductivity < 50 µS/cm
Repeatability 0.2 % FSR , for rod length ≥ 500mm
1 mm , for rod length < 500mm
Step response time, T90 ≤ 100 ms
Damping ≤ 60 s
IO-Link interface
IO-Link version 1.1
Device profile Smart Sensor Profile
IO-Link port type Class A
Baud rate 38,4 kbaud (COM2)
SIO-mode Yes
Process data (cyclic) Process Value
Device Status
Adjustable data (acyclic) Sensor Adjustment
Switch parameters
Analog Output Signal Adjustment
Analog Output Signallimits (Minimum, Maximum, Alarm)
Process connection
Wetted parts material AISI 316L (1.4404)
PEEK Natura
Surface roughness wetted parts Ra ≤ 0.8 µm
Ra ≤ 0.4 µm, for rod length till 100 cm
Output signal
Output signal 4 … 20 mA
Output type PNP
NPN
Digital (push-pull)
Off
Switching logic High-Active
Low-Active
Compliance and approvals
EMC Emission EN 61326
EMC Immunity EN 61326
Hygiene 3-A (74-07)
EHEDG (pending)