Level measurement

คุณสมบัติสินค้า:

PLP70H

Point level sensors

หมวดหมู่ : Process sensors Level sensors

แบรนด์ : Baumer

Share

Potentiometric level measurement

  • Potentiometric Level Transmitter
  • IO-Link Dual Channel (4 … 20 mA)
  • Compact, food compatible, hygienic design
  • Wetted parts in acid-proof, stainless steel and PEEK
  • 3-A approved / FDA and EHEDG compliant
  • Defined empty registration
  • Unaffected by strong adhesive media
  • Configurable measuring range

Technical data

Performance characteristics
Measuring principle                                   Potentiometric level measurement
Media characteristics                                 ≥ 5 µS/cm
Measuring range                                       200 … 3000 mm
Max. measuring error                                 ± 1 % FSR ,for media conductivity ≥ 50 µS/cm
                                                             ± 3 % FSR ,for media conductivity < 50 µS/cm
Repeatability                                            0.2 % FSR , for rod length ≥ 500mm
                                                             1 mm , for rod length < 500mm
Step response time, T90                             ≤ 100 ms
Damping                                                  ≤ 60 s

IO-Link interface
IO-Link version                                          1.1
Device profile                                            Smart Sensor Profile
IO-Link port type                                       Class A
Baud rate                                                 38,4 kbaud (COM2)
SIO-mode                                                 Yes
Process data (cyclic)                                   Process Value
                                                              Device Status
Adjustable data (acyclic)                              Sensor Adjustment
                                                              Switch parameters
                                                              Analog Output Signal Adjustment
                                                              Analog Output Signallimits (Minimum, Maximum, Alarm)

Process connection
Wetted parts material                                 AISI 316L (1.4404)
                                                              PEEK Natura
Surface roughness wetted parts                    Ra ≤ 0.8 µm
                                                              Ra ≤ 0.4 µm, for rod length till 100 cm

Output signal
Output signal                                            4 … 20 mA
Output type                                              PNP
                                                              NPN
                                                              Digital (push-pull)
                                                              Off
Switching logic                                          High-Active
                                                              Low-Active

Compliance and approvals
EMC Emission                                            EN 61326
EMC Immunity                                           EN 61326
Hygiene                                                   3-A (74-07)
                                                              EHEDG (pending)

Data sheet - PLP70H                                  Download