PF75H
Flow sensors & Flow meters
หมวดหมู่ : Process sensors ,  Flow sensors & Flow meters , 
แบรนด์ : Baumer
Share
Electromagnetic flow meter for hygienic applications
Technical data
Performance characteristics
Measuring principle Electromagnetic flow measurement
Max. flow velocity 10 m/s
Media characteristics ≥ 5 µS/cm
Measuring range, flow 0 … 10 m/s
0 … 288 m3/h
Min. measuring span 0 … 10.3 l/h
Hysteresis 3 % o. r.
Max. measuring error ± 0.5 % o. r.
± 0.2 % o. r. , optional
Max. turndown ratio 1 : 1000
Repeatability ≤ 0.1 % o. r.
Step response time ≤ 400 ms
Sampling interval ≤ 200 ms
Damping 0.2 … 1000 s
Process conditions
Process temperature -20 … 100 °C
SIP/CIP compatibility < 30 min, in general @ medium temperature up to 130 °C
Ambient conditions
Degree of protection (EN 60529) IP 65
IP 67
Compliance and approvals
EMC IEC 61326-1
EN 61326-1
Hygiene 3-A (28-06)