TE2
Temperature
หมวดหมู่ : Process sensors ,  Temperature sensors , 
แบรนด์ : Baumer
Share
Compact RTD temperature sensor
Technical data
Performance characteristics
Process temperature Refer to section "Operating conditions"
Pt100 accuracy class (EN 60751) B (± 0.3 °C at 0 °C)
± (0.3 + 0.005 × t)°C
A (± 0.15 °C at 0 °C)
± (0.15 + 0.002 × t)°C
1/3 B (± 0.1 °C at 0 °C)
± 1/3 × (0.3 + 0.005 × t)°C
1/6 B (± 0.05 °C at 0 °C)
± 1/6 × (0.3 + 0.005 × t)°C
Thermal response time, T90 RTD element only
≤ 3.0 s , Ø3 mm
≤ 3.6 s , Ø4 mm
≤ 8.5 s , Ø6 mm
Thermal response time, T50 RTD element only
≤ 1.0 s , conical sensor
≤ 1.3 s , Ø3 mm
≤ 2.5 s , Ø4 mm
≤ 3.0 s , Ø6 mm
Process pressure Refer to section "Operating conditions"
Process connection
Sensor length ≤ 3000 mm
Sensor tube material AISI 316L (1.4404)
Surface roughness wetted parts Ra ≤ 0.8 µm
Ambient conditions
Degree of protection (EN 60529) IP 65 , with DIN EN 175301-803 A (DIN 43650 A), 4-pin
IP 68 , with M12-A, 4-pin and appropriate cable
Humidity ≤ 100 % RH , condensing
Long-term test (transmitter) IEC 770 6.3.2
Vibration (sinusoidal) (EN 60068-2-6) 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
Output signal
Without transmitter 1 x Pt100, 4-wire
With transmitter 4 … 20 mA , 2-wire
Compliance and approvals
EMC EN 61000-6-2
EN 61000-6-3
EN 61326-1
NE21
Hygiene FDA (21 CFR 177.2415)
3-A (74-07)
Railway applications EN 50155
Explosion protection Ex ia Simple apparatus, gas and dust
Data sheet - TE2 Download