Front-flush and low-invasive resistance thermometers

  • Optimum placement even in stirrers and pigging systems
  • Integrated 4 ... 20 mA transmitter or Pt100 output
  • Very fast response time
  • 3-A-compliant without elastomers

Technical data

Performance characteristics
Process temperature                                115 … 135 °C , < 1 h
                                                           -40 … 115 °C , permanent
Min. output span                                     25 °C
Pt100 accuracy class (EN 60751)                  B (± 0.3 °C at 0 °C)
                                                           ± (0.3 + 0.005 × t)°C
                                                           A (± 0.15 °C at 0 °C)
                                                           ± (0.15 + 0.002 × t)°C
                                                           1/3 B (± 0.1 °C at 0 °C)
                                                           ± 1/3 × (0.3 + 0.005 × t)°C
                                                           1/6 B (± 0.05 °C at 0 °C)
                                                           ± 1/6 × (0.3 + 0.005 × t)°C
Max. conversion error                               ± 0.25 °C
Max. output error                                    ± 0.1 % FSR
                                                           ± 0.016 mA
Temperature drift (by ambient)                  < 0.003 % FSR/°C , typ.
                                                          < 0.01 % FSR/°C , max.
Thermal response time, T90                     ≤ 6.5 s , 20 mm
                                                          ≤ 6.7 s , 50 mm
                                                          ≤ 66.0 s , front-flush
Thermal response time, T50                     ≤ 2.5 s , 20 mm.
                                                          ≤ 2.7 s , 50 mm
                                                          ≤ 9.0 s , front-flush
Sampling interval                                    0.5 s

Process connection
Immersion length                                   0 mm , front-flush
                                                          20 mm
                                                          50 mm
Sensor tube material                               AISI 316L (1.4404)
Wetted parts material                              PEEK Natura
Surface roughness wetted parts                Ra ≤ 0.8 µm

Ambient conditions
Degree of protection (EN 60529)               IP67
                                                          IP69K , with appropriate cable
Humidity                                               < 98 % RH , condensing
Vibration (sinusoidal) (EN 60068-2-6)          1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.

Output signal
Without transmitter                                 1 x Pt100, 4-wire
With transmitter                                     4 … 20 mA , 2-wire
Shunt resistance                                     Rs ≤ (Vs - 8 V)/0.023 A
                                                          Rs ≤ 680 Ohm, Vs = 24 V DC

Compliance and approvals
EMC                                                    EN 61000-6-2
                                                          EN 61000-6-3
                                                          EN 61326-1
Hygiene                                               FDA (21 CFR 177.2415)
                                                          3-A (74-07)

Data sheet - TER8                                     Download