Flow sensor

คุณสมบัติสินค้า:

Programmable flow sensors

Flow sensors & Flow meters

หมวดหมู่ : Process sensors Flow sensors & Flow meters

Share

คุณสมบัติ

General information
Range of application                         Conductive liquid media (conductivity: >= 20 µS/cm / viscosity: < 70 mm²/s at 40°C)
Flow measuring range                        0.1 ... 25 l/min
Parametrisation options                      Hysteresis / window
                                                     Normally open / Normally closed
                                                     Switching logic
                                                     Display can be turned off
                                                     Current/ voltage /pulse output
                                                     Start-up suppression time
                                                     Display unit
                                                     Totaliser function
Temperature measuring range min.       -20 °C
Temperature measuring range max.       80 °C

Outputs / inputs


Pulse output                                    Yes
Counter reset                                  Yes
Switching output                              2 x normally closed / normally open programmable
Analogue output                              4 ... 20 mA
                                                    0 ... 10 V
                                                    Programmable
                                                    Scalable
Comment on analogue output            When used with an analog output use exclusively sensor cables without LED
IO-Link                                          Yes

 
Electrical data


Operating voltage                          19 ... 30 V DC
Voltage type                                 Direct voltage (DC)
Electrical design                            PNP
                                                  NPN*
                                                  *Programming buttons
                                                  *IO-Link parameterisation
Current carrying capacity max.          2 x 200 mA
Voltage drop max.                          2 V
Current consumption max.                95 mA
Protection class                              III
Short-circuit protection                    Yes
Overload-proof                               Yes
Reverse polarity protection               Yes

Mechanical data


Materials in contact with the medium      V4A (1.4404)
                                                       FKM
                                                       PEEK
Material of housing                              V4A (1.4404)
                                                       FKM
                                                       PC
                                                       PBT-GF 20
Electrical connection                            M12
                                                       4-pin
                                                       Contacts gold-plated
Pressure resistance                              16 bar
Process connection                              Flat sealing
                                                       External thread
                                                       G 1/2

 
Accuracy


Resolution                                        0.05 l/min | 0.2 °C
Reproducibility                                  ± 0.2% MREV * (flow monitoring)
Response dynamics of T05 / T09         T09 = 20 s (temperature monitoring)
Comment                                         * MV = measured value, MREV = measurement range end value
Accuracy                                          ± (0.8 % MV + 0.5 % MREV * | ± 2.5 °C
Ready delay                                      5 s
Response time                                   0.15 s (flow monitoring

Ambient conditions


Ambient temperature min.                  -10 °C
Ambient temperature max.                  60 °C
Protection rating                                IP67